KB2026002: How to model condensation

The way of modeling condensation depends on where condensation occurs, that is:


  1. Condensation at wall surfaces or solid/fluid contact interfaces
  2. Condensation away from wall surfaces or solid/fluid contact interfaces


1. Condensation at wall surfaces or solid/fluid contact interfaces

Condensation at wall surfaces or solid/fluid contact interfaces can be simulated using different models.


Modeling Fluid Film Condensation

Simcenter STAR-CCM+ provides an evaporation and condensation model for fluid films. The fluid film model accounts for transport of mass, momentum and energy, The evaporation and condensation model is a Film-Eulerian Phase Interaction model between the liquid film and a multi-component gas. Following important points should be kept in mind when simulating condensation/evaporation with the Simcenter STAR-CCM+ Fluid Film model:

  • The fluid film evaporation and condensation model is valid only for temperatures below the boiling temperature of any of the fluid film components.
  • The analyses have to be carried out transient.

Modeling Thin Film Fogging

In almost all environmental conditions air contains a certain amount of water vapour (humidity). The water vapour might condense and create a water film at surfaces if the surface temperature is below air temperature. Simcenter STAR-CCM+ offers a simplified approach to simulate the condensation/evaporation of water vapour at surfaces using the Thin Film Defogging model.

The Thin Film Defogging model is based on solving an additional scalar transport equation that represents the mass fraction of water vapour. A source/sink term for the scalar is considered for condensation/evaporation as well as the latent heat required for transition. The water film layer is not represented as a phase in the inner volume mesh, but is modeled by functions, thus the water film layer does not flow.

Following important points should be kept in mind when simulating condensation/evaporation with the Simcenter STAR-CCM+ Thin Film Defogging model:

  • Condensation/evaporation is an intrinsically transient phenomenon. Therefore, simulations should be run in transient mode.
  • Condensation/evaporation can only be applied to wall and solid/fluid contact interfaces.
  • A steady state calculation without condensation/evaporation should be performed first to initialize the convection flow field.
  • During the transient run it is advisable to leave all equations on, but a large time-step can be used because the condensation/evaporation does not affect the flow field.
  • Currently the saturation vapour pressure curve is based on water vapour.

 

 2) Condensation away from wall surfaces or solid/fluid contact interfaces

 Condensation/evaporation away from wall surfaces or solid/fluid contact interfaces can be simulated using various models:

  • The Simcenter STAR-CCM+ Lagrangian Multiphase model can be used if liquid droplets exists in the domain. Condensation/evaporation occurs at the droplet surface with mass and energy transfer between droplet and ambient gas.
  • The Simcenter STAR-CCM+ VOF Multiphase Boiling model can be used if there are two or more immiscible fluid phases. Condensation/evaporation occurs at the liquid-vapour interface.
  • The Simcenter STAR-CCM+ Multiphase Segregated Flow model (Eulerian Multiphase model) with an inter-phase mass and energy transfer model if phases are mixed on small length scales.
Tags
KB-2026001: How to Submit and Monitor Feko Jobs on an HPC Cluster
KB-2026003: How to Manage Restart Files and Restart a Radioss Simulation