KB-2026004: How to Apply Temperature Loads in OptiStruct – Understanding Temperature Subcase Options

1. Overview

OptiStruct provides different options for defining temperature conditions in structural analyses. These options allow engineers to specify initial temperatures, account for temperature-dependent material properties, and apply thermal loads to calculate temperature-induced structural responses.

The TEMPERATURE Subcase Information Entry is used to select the temperature field for either material property calculations or thermal loading.

Depending on the analysis type and simulation requirements, the following temperature options are available:

  • INITIAL

  • MATERIAL

  • LOAD

  • BOTH

Additional options such as HTIME and TEMPT are available for specific thermal analysis workflows.

This guide explains these options, their differences, and their applicability across different OptiStruct analysis types.

2. Understanding the TEMPERATURE Entry

The general syntax is:

TEMPERATURE(type, SUBTYPE=subtype_option) = SID

Where:

  • type: Specifies how the temperature field is used.

  • SUBTYPE: Specifies an additional temperature selection method, where applicable.

  • SID: Identification number of the temperature definition or referenced thermal subcase.

The temperature field can be defined using Bulk Data entries such as TEMP, TEMPD, TEMPADD, TEMPT, and TEMPSEC. It can also reference a transient heat transfer subcase or a TSTRU Subcase Information Entry, where supported.

3. Different Temperature Options

3.1 TEMP(INITIAL) – Initial Temperature

This option defines the initial temperature distribution of the model.

Purpose:

  • Establishes the initial temperature condition before thermal loading is applied.

  • Defines the initial temperature used in thermal strain calculations.

  • Can be used with temperature-dependent material properties through the appropriate material definitions.

Example:

TEMPERATURE(INITIAL) = 5

Alternatively, the initial temperature can be defined using the TREF field in the material entry.

When to use:

When the model needs an initial temperature condition that serves as the starting reference for subsequent temperature changes.

3.2 TEMP(MATERIAL) – Temperature-Dependent Material Properties

This option uses the selected temperature field to determine temperature-dependent material properties defined through the MATTi Bulk Data entries.

Purpose:

  • Updates material properties based on the selected temperature field.

  • Allows material properties such as elastic modulus and thermal expansion characteristics to vary with temperature.

  • Can reference a thermal analysis subcase in linear analysis.

Example:

TEMPERATURE(MATERIAL) = 7

When to use:

When material properties need to be evaluated at a specified temperature, particularly when temperature-dependent material data are defined.

Important: This option is supported for linear analysis. For nonlinear analysis, TEMP(LOAD) is used to update temperature-dependent material properties.

3.3 TEMP(LOAD) – Thermal Loading

This option applies the selected temperature field as an equivalent static thermal load.

Purpose:

  • Calculates thermal strains resulting from the temperature difference.

  • Evaluates structural deformation caused by thermal expansion or contraction.

  • Calculates thermal stresses when thermal expansion is restricted or when temperature variations occur across the structure.

Example:

TEMPERATURE(LOAD) = 4

When to use:

When the objective is to evaluate the structural response caused by an applied temperature distribution.

This is the option used in the attached FEM example for linear static thermal stress analysis.

3.4 TEMP(BOTH) – Material Properties and Thermal Loading

This option uses the same temperature field for both material property calculations and thermal loading.

Purpose:

  • Updates temperature-dependent material properties.

  • Applies the temperature field to calculate thermal strains.

  • Combines the functionality of TEMP(MATERIAL) and TEMP(LOAD).

Example:

TEMPERATURE(BOTH) = 7

When to use:

When both temperature-dependent material properties and thermal loading need to be considered using the same temperature field.

Note: BOTH is the default type when the temperature type is not explicitly specified. For clarity, explicitly specifying the intended option is recommended.

4. Additional Temperature Subtype Options

Apart from the four main temperature options, OptiStruct provides HTIME and TEMPT for specific thermal loading workflows.

4.1 HTIME=ALL

This option selects all output time steps from a transient thermal subcase.

Example:

TEMPERATURE(LOAD,HTIME=ALL) = 8

Purpose:

  • Reads the temperature fields from all available output time steps of a transient thermal analysis.

  • Allows the temperature history to be considered in thermal stress analysis.

  • Supports linear and nonlinear static analysis.

When to use:

When temperature results from multiple time steps of a transient thermal analysis need to be used in a structural analysis.

4.2 TEMPT

This option is used when grid temperature values are provided through an external file or an internal transient thermal subcase.

Example:

TEMPERATURE(LOAD,TEMPT) = 23

Here, the referenced SID identifies the corresponding TEMPT Bulk Data definition.

Purpose:

  • Reads predefined grid temperature values at different time steps.

  • Supports temperature mapping from external files or internal transient thermal analysis.

  • Allows temperature data to be mapped to the structural analysis according to the mapping rules defined in the TEMPT entry.

When to use:

When performing nonlinear static or nonlinear transient thermal stress analysis using predefined temperature histories.

5. Comparison of Temperature Options

Option Primary purpose
TEMP(INITIAL) Defines the initial temperature distribution
TEMP(MATERIAL) Evaluates temperature-dependent material properties
TEMP(LOAD) Applies temperature as a thermal load
TEMP(BOTH) Uses the temperature field for both material properties and thermal loading
TEMP(LOAD,HTIME=ALL) Selects all output time steps from a transient thermal subcase
TEMP(LOAD,TEMPT) Uses predefined temperature histories through a TEMPT definition

6. Applicability Across Different Analysis Types

Not all temperature options are supported in every analysis type.

The following table summarizes the applicability specified in the OptiStruct documentation.

Temperature option Linear Static Linear Transient Nonlinear Static Nonlinear Transient Explicit Dynamic
INITIAL Yes Yes Yes Yes Yes
MATERIAL Yes Yes No No No
BOTH Yes No No No No
LOAD Yes No Yes No No
LOAD, HTIME=ALL Yes No Yes No No
LOAD, TEMPT No No Yes Yes No

Important: In transient structural analyses, temperature loading can also be introduced through DLOAD, using TLOAD entries that reference temperature Bulk Data definitions. This is an alternative to the direct temperature subcase options shown above.

7. Important Considerations

  • Only one of TEMP(MATERIAL) or TEMP(INITIAL) is allowed in a model.

  • TEMP(MATERIAL) and TEMP(BOTH) cannot be used within nonlinear static analysis subcases.

  • TEMP(MATERIAL), TEMP(BOTH), and TEMP(LOAD) cannot be used within nonlinear transient analysis subcases.

  • In linear static analysis, TEMP(INITIAL) takes precedence over TREF when defining the initial temperature.

  • When both TEMP(BOTH) and TEMP(LOAD) are specified, the last applicable entry determines the load temperature.

  • Ensure that temperature load set IDs and other static load set IDs are unique.

  • For nonlinear analyses, the thermal expansion coefficient is treated as a secant value, and the thermal strain formulation depends on the PARAM,THMLSTN setting.


Attached Files
Thermal_Stress.zip
2.24 MB
Tags
KB-2026003: How to Manage Restart Files and Restart a Radioss Simulation